<LOGO>
FM Transmitter Measurement Report
Created: 2024-10-17 22-11-55
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
107.20 MHz 4/5, 57 dBuV RMC
Pilot RDS Phase Difference
0.0 kHz 3.2 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
3 kHz 69 kHz 16891 0,0059
Modulation Power
Limit Measuring Tolerance
10,0 dBr 3,0 dBr
MIN AVE MAX % above 13,0 dBr
3,8 dBr 5,30 dBr 6,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RMC " F216 0 (No PTY) 1 0 1 2 22:11, 17.10.2024
RT
"RMC BLOIS 107.2 "
AF EON
90.1, 90.2, 93.7, 95.3, 96.5, 96.8, 99.6, 100.7, 101.2, 101.6, 103.1, 103.2, 103.7, 103.9, 107.2, 107.3, 107.5 MHz -
FM Scope Station: 107.20 MHz, signal: 4/5 (57 dBuV) Max at: 69 kHz MIN: 3 kHz % above 75 kHz: 0,0059 Acquired: 2024/10/17 22:10:52 Total samples: 16891 Equivalent time: 0:14:04 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000
FM Scope MAX: 6,9 dBr MIN: 3,8 dBr AVE: 5,30 dBr % above 13,0 dBr: 0,0 Last value: 6,8 dBr (2024/10/17 22:10:51) Station: 107.20 MHz, signal: 4/5 (57 dBuV) 21:58 22:00 22:02 22:04 22:06 22:08 22:10 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality